Zhuozhou Tianpeng Imp. And Exp. Trade Co., Ltd.
Main products:Cube Mould,Concrete Test Hammer
Products
Contact Us
  • Contact Person : Mr. Chen Jie
  • Company Name : Zhuozhou Tianpeng Imp. And Exp. Trade Co., Ltd.
  • Tel : 86-312-3852880,13131251619
  • Fax : 86-312-3868882
  • Address : Hebei,zhuozhou,No472, Fanayng Mid Rd,Zhuozhou City,Hebei Province,China
  • Country/Region : China

TP50(+)Reinforcement position tester

TP50(+)Reinforcement position tester
Product Detailed
TP50(+)Reinforcement position tester: 1.concrete cover thickness 2. concrete internal reinforcement position 3. corrosion

TP50(+)Reinforcement position tester :

 

 

Adoption standard

 

GB50204-2002

 

GB50010-2002

 

GB/T50344-2004

 

JGJ/T152-2008

 

DB11/T365-2006

 

 

 

Product usage

 

Testing concrete cover thickness

 

Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.

 

Estimation bar diameter

 

Detection of Cable and Plumbing pipe

 

 

Features

 

investigation depth could reach 180mmSingle comprehensive probe. No need to replace during test.back-lit screen let instrument can be normal used under the condition of insufficient lightMachine software is complete .The report could be printed automatically connecting with computer

 

 

Work environment condition

 

No strong alternating electromagnetic field

 

No corrosive gas in the air.

 

Avoid larger vibration and impact

 

Avoid the LCD panel contact with sunlight directly

 

Main performance index

 

Number

Item

SPEC

1

Bar diameter application range(mm)

Φ6 – Φ50

2

maximum value permissible error of Bar diameter

≤±1

3

Protective layer thickness measuring range

 

The first measuring range (mm)

6 - 90

The second measuring range (mm)

7-180

4

The maximum error of reinforced protective layer thickness test value

 

The first measuring range (mm)

The second measuring range (mm)

 

6 - 59

7 - 79

≤±1

60 - 69

80 - 119

≤±2

70 -90

120 - 180

≤±4

5

Work environment condition

 

Work temperature °C

-10 - +40

relative humidity RH

< 90%

6

power supply mode

Alkaline cell X 6

 

 

 

Standard configuration

 

Instruction, software, test probe, transmission line

 